Tools · Energy

Heat rate and efficiency calculator

Convert between heat rate and efficiency, calculate a unit's performance from its operating data and estimate what each point of degradation costs.

1. Direct conversion

2. From operating data

3. Cost of degradation

1. Conversion
2. Unit performance
3. Cost

How it is calculated

  • Efficiency = 3,600 ÷ heat rate, with heat rate in kJ/kWh. The example values are those of the gas turbine in our heat rate article.
  • Use the lower heating value (LHV) and net power to get the net heat rate on an LHV basis. If you use the higher heating value or gross power, state it when comparing figures.
  • The cost of degradation assumes the same generation: 1% more heat rate means 1% more fuel.

Read our article: heat rate, what it is, how it is calculated and what degrades it →

For reference only. Results are calculated in your browser and do not replace professional judgement or the design and test data of your equipment. Delta Mechanics accepts no liability for decisions based on this tool alone.

← All tools

How much heat rate is your unit losing?

We measure its performance, correct it to reference conditions and quantify what can be recovered.

Request a technical meeting